Compare Products Up to 4
Clear All

Mixed Gases

10% Carbon Dioxide 21% Oxygen Balance Nitrogen Certified Standard Mixture, Size 200 Cylinder, CGA-590

Show Full Description Hide Full Description

Compare
10% Carbon Dioxide 21% Oxygen Balance Nitrogen Certified Standard Mixture, Size 200 Cylinder, CGA-590

SDS

10% Carbon Dioxide 21% Oxygen Balance Nitrogen Certified Standard Mixture, Size 200 Cylinder, CGA-590

Show Full Description Hide Full Description

Airgas Part #:X03NI69C2001280

Loading

CT 1% HYDROGEN 10% METHANE 20% ETHYLENE BALANCE PROPANE SIZE 150A CERTIFIED STANDARD-SPEC CGA 350 NOVA, GEISMAR BLEND ITEM NUMBER 72A BLEND +/-5% ANALYTICAL +/-2% DEW POINT 40 DEG F MAINTAIN CYLINDER AT OR ABOVE 70F TO PREVENT COMPONENT CONDENSATION AND CALIBRATION ERROR CUSTOM MIX

Show Full Description Hide Full Description

Compare
CT 1% HYDROGEN 10% METHANE 20% ETHYLENE BALANCE PROPANE SIZE 150A CERTIFIED STANDARD-SPEC CGA 350 NOVA, GEISMAR BLEND ITEM NUMBER 72A BLEND +/-5% ANALYTICAL +/-2% DEW POINT 40 DEG F MAINTAIN CYLINDER AT OR ABOVE 70F TO PREVENT COMPONENT CONDENSATION AND CALIBRATION ERROR CUSTOM MIX

SDS

CT 1% HYDROGEN 10% METHANE 20% ETHYLENE BALANCE PROPANE SIZE 150A CERTIFIED STANDARD-SPEC CGA 350 NOVA, GEISMAR BLEND ITEM NUMBER 72A BLEND +/-5% ANALYTICAL +/-2% DEW POINT 40 DEG F MAINTAIN CYLINDER AT OR ABOVE 70F TO PREVENT COMPONENT CONDENSATION AND CALIBRATION ERROR CUSTOM MIX

Show Full Description Hide Full Description

Airgas Part #:X04PR69C15AC000

Loading

PH 0.45% N BUTANE 0.45% N PENTANE 2.25% PROPANE 10.25% ETHANE 32.5% METHANE BALANCE HYDROGEN SIZE 150A PRIMARY HYDROCARBON CGA 350 FLAREAL BTU REFERENCE STANDARD- HIGH TARGET BTU VALUE: 1,191.5 BTU/SCF NET IDEAL, DRY (ADJ H2 @ 1,212 BTU/SCF) MAINTAIN CYLINDER ABOVE 0F OR HYDROCARBON CONDENSATION AND CALIBRATION ERRORS MAY OCCUR PROVIDE RSR BTU REPORT @ 14.696 PSIA W/ COA CUSTOM MIX

Show Full Description Hide Full Description

Compare
PH 0.45% N BUTANE 0.45% N PENTANE 2.25% PROPANE 10.25% ETHANE 32.5% METHANE BALANCE HYDROGEN SIZE 150A PRIMARY HYDROCARBON CGA 350 FLAREAL BTU REFERENCE STANDARD- HIGH TARGET BTU VALUE: 1,191.5 BTU/SCF NET IDEAL, DRY (ADJ H2 @ 1,212 BTU/SCF) MAINTAIN CYLINDER ABOVE 0F OR HYDROCARBON CONDENSATION AND CALIBRATION ERRORS MAY OCCUR PROVIDE RSR BTU REPORT @ 14.696 PSIA W/ COA CUSTOM MIX

SDS

PH 0.45% N BUTANE 0.45% N PENTANE 2.25% PROPANE 10.25% ETHANE 32.5% METHANE BALANCE HYDROGEN SIZE 150A PRIMARY HYDROCARBON CGA 350 FLAREAL BTU REFERENCE STANDARD- HIGH TARGET BTU VALUE: 1,191.5 BTU/SCF NET IDEAL, DRY (ADJ H2 @ 1,212 BTU/SCF) MAINTAIN CYLINDER ABOVE 0F OR HYDROCARBON CONDENSATION AND CALIBRATION ERRORS MAY OCCUR PROVIDE RSR BTU REPORT @ 14.696 PSIA W/ COA CUSTOM MIX

Show Full Description Hide Full Description

Airgas Part #:X06HY54P15AC000

Loading